Description
The Automatic Water Level Controller 9526 MT is a smart device designed to monitor and manage water levels in tanks
Specification Of Automatic Water Level Controller 9526 MT
Operating Voltage (AC) | 115V to 270V |
Connected Load | 15 Amp |
Resistive Load | 15 Amp |
Direct Load (1 Phase) | 1 HP |
Indirect Load (Contactor coil) (1 or 3 Phase) | Any Size |
Dry Run Protection | Yes |
High Voltage Cut-off (AC) | 260 V |
Low Voltage Cut-off (AC) | 160 V |
Starter Timer | Yes * |
Ingress Protection | IP41** |
Dimension | |
Height (mm) | 170 |
Width (mm) | 125 |
Depth (mm) | 47 |
WaterSwitch System Operation
Description of Controls and Indications in Controller:
1) Manual – Off/Reset – Auto Switch
Off/Reset Mode: The controller function is Off and the pump will not run in this mode. Also used
to Reset when the Dry Run Tripped.
Auto Mode: The controller function is in automatic mode and the motor is On/Off and
tank filling function will take place automatically depending on the
tank level, voltage conditions, etc.
Manual Mode: The controller function is overridden and pump control output is
continuously on irrespective of the water level in the overhead tank,
sump, and well. The low voltage high voltage and Dry Run Protection
for the motor will not be available in this mode.
2) Indicators:
Pump On/Output On: Indicates the Controller output is “ON” thus the
pump is ON
Dry Run: Indicates Controller Tripped (Auto Mode) due to
Dry Run (or Indicates Running Dry in Manual
Mode)
High Voltage: Indicates the mains voltage is very high (motor is
“Cut Off” if the controller is in “Auto” mode)
Low Voltage: Indicates the mains voltage is very low (motor is
“Cut Off if the controller is in “Auto” mode)
Sump Empty: Indicates Sump/Well is empty.
Tank Full: Indicates the overhead tank is full.
Auto: Indicates the control function is in automatic mode